List of Files for XyWrite v.4.017 (XY4017.FIL)

????????.LOG
User login file. Name selected by users. In network installations, stored in userlog directory during server installation.
Required to run XWSTART.INT successfully. Do not delete.

ADDENDUM.DOC
Newsletter information.

ADDRESS.FRM
Sample address form in XyWrite.

ARTICLE.DOC
This article outlines a few of the special functions of XyWrite.

BUSINESS.SPL
Editable spelling dictionary with words common in business.
Delivered with spelling module.

BX230003.SPD
Bitstream Speedo printer and screen font: Swiss.
Delivered with screen fonts module. Required for graphic view unless user has other screen fonts.

BX230004.SPD
Bitstream Speedo printer and screen font: Swiss Italic.
See previous entry.

BX230005.SPD
Bitstream Speedo printer and screen font: Swiss Bold.
See previous entry.

BX230006.SPD
Bitstream Speedo printer and screen font: Swiss Bold Italic.
See previous entry.

BX230011.SPD
Bitstream Speedo printer and screen font: Dutch.
See previous entry.

BX230012.SPD
Bitstream Speedo printer and screen font: Dutch Italic.
See previous entry.

BX230013.SPD
Bitstream Speedo printer and screen font: Dutch Bold.
See previous entry.

BX230014.SPD
Bitstream Speedo printer and screen font: Dutch Bold Italic.
See previous entry.

BX230419.SPD
Bitstream Speedo printer and screen font: Courier.
See previous entry.

BX230582.SPD
Bitstream Speedo printer and screen font: Courier Italic.
See previous entry.

BX230583.SPD
Bitstream Speedo printer and screen font: Courier Bold.
See previous entry.

BX230611.SPD
Bitstream Speedo printer and screen font: Courier Bold Italic.
See previous entry.

CAD.TPF
Used in graphics conversion.
Delivered with graphics conversion modules.

CHARSET
Chart showing all characters available when using XyWrite fonts.

COLOR.DSP
Generic color display.

CVT.RES
Import graphics conversion filter.

DATABASE.FLT
Calls the corrosponding Word for Word import filter when selected from Import Database option from the menu.

DEFAULT.FNT
Used when a font is not selected.

DEFAULT.TPF
Used in graphics conversion.
Delivered with graphics conversion modules.

DICT.HYP
Editable dictionary for setting hyphenation points.
Delivered with hyphenation module. If deleted, hyphenation will depend completely on internal hyphenation algorithm.

DICT.SPL
Non-editable spelling dictionary. Can not be modified.
Delivered with spelling module. Required for spell-check.

EDITOR.EXE
Main executable of XyWrite for Windows. Not editable.
Required to boot. Do not delete.

ERROR.MSG
Prompts used during the installation of Bitstream fonts.

FAX.TPL
Fax cover sheet.

FUNC.HLP
Help menu that is accessed by press a function key alone or with the key combinations listed below to perform the described action.

G-SCALE.DSP
Gray scale monitor display file.

GAS.DSP
Works well with the IBM P.70 Gas Plasma Display, with a GA setting of VG.

GENERIC.PRN
Generic printer driver that supports Courier, Dutch, and Swiss with available attributes of: bold, forms, and underline.

GRA-REV.DSP
Gray scale monitor display file with reverse display colors.

GRID
Visual aid for designing forms; mentioned in reference guide.

IBM2TIF.EXE
Graphics conversion file.

IBM2TIF.SET
Contains information needed in the graphics conversion process.

LCD.DSP
This file is for use on an LCD display monitor that emulates CGA and uses an GA setting of EG.

LEGAL.SPL
Editable spelling dictionary with words common in legal settings.
Delivered with spelling module.

LETTER.DOC
Sample letter in XyWrite.

LETTER.TPL
Series of designs for letterheads.

LILGUY.PCX
Graphic file in PC Paintbrush format.
Delivered with sample graphics module.

LITEBULB.TIF
Graphic file in Tagged Image Format.
Delivered with sample graphics module

LOG.LOG
Dummy log file.

MAIL.PRN
Use this file to strip all format commands and character modes. The effects of the format commands are carried out, however, the character mode information is lost. Used to convert a file so that it can be sent over an electronic mail service.

MEMO.TPL
Series of designs for memoranda.

MONO.DSP
Generic monochrome display.

NCP2X.EXE
Converts between code pages.

PARTY.CGM
Graphics file in Computer Graphic Metafile format.
Delivered with sample graphics module.

PERS.SPL
Editable spelling dictionary commonly misspelled words and their correct spellings.
Delivered with spelling module.

PICTURE.TIF
Graphics file in Tagged Image Format.
Delivered with sample graphics module.

PLOTTER.TPF
Used in graphics conversion.
Delivered with graphics conversion modules.

README.FLT
The following file describe information related to XyWrite's Import/Export conversions that are not reflected in the documentation.

README.PRN
The following file describe XyWrite printer notes that are not reflected in the documentation.

README.PUB
The following file describes XyWrite product notes that are not reflected in the documentation.

REPORT.TPL
Format for a report.

SAMPLE.DOC
This is a sample file in XyWrite.  You can use it to learn to identify the parts of the main screen.

SAMPLE.SET
Sample file of a Custom Command Set that allows you to: create new commands, redefine XyWrite commands, redefine XyWrite function calls.  See the XyWrite 4.0 Customization Guide for details on how Custom Command Sets work.

SAVEGET.SGT
Collection of canned save/get (text macros)
OK to delete but XWSTART.INT should be modified so it does not try to load it any more.

SETTINGS.DFL
Contains all custom settings. Can be edited by user directly or via the menus. This file is generated from "Defaults" in the  Options menu.
Read-only file. Keep in case of disaster with customizing XWSET.DFL.

SETTINGS.XY4
This file duplicates SETTINGS.DFL created by install.
Do not remove.

SPREAD.FLT
Calls the corrosponding Word for Word import filter when selected from Import Spreadsheet option from the menu.

STANDARD.PRN


STARTUP.INT
XPL program automatically run each time XyWrite is booted. Can be edited by user.
OK to delete if user has alternative file.

STRIP.PRN
Use this file to strip all format commands and character modes. The effects of the format commands are carried out, however, the character mode information is lost. Used to produce a pure ASCII file.

TEXTIN.FLT
Calls the corrosponding Word for Word import filter when selected from Import Text option from the menu.

TEXTOUT.FLT
Calls the corrosponding Word for Word export filter when selected from Import Text option from the menu.

W4W04F.EXE
WordStar 3.30 to 6.00 import filters.
Delivered only if selected as part of text conversion module. Required for this conversion only.

W4W04T.EXE
WordStar 3.30 to 6.00 export filters.
See previous entry.

W4W05F.EXE
Word 3.0, 3.1, 4.0, 5.0, 5.5 import filters.
See previous entry.

W4W05T.EXE
Word 3.0, 3.1, 4.0, 5.0, 5.5 import filters.
See previous entry.

W4W06F.EXE
WordPerfect 4.1, to 4.2 import filter.
See previous entry.

W4W06T.EXE
WordPerfect 4.1, to 4.2 export filter.
See previous entry.

W4W07F.EXE
WordPerfect 5.0, to 5.1 import filter.
See previous entry.

W4W07T.EXE
WordPerfect 5.0, to 5.1 export filter.
See previous entry.

W4W10F.EXE
MultiMate 3.3, 4, Advantage, II import filter.
See previous entry.

W4W10T.EXE
MultiMate 3.3, 4, Advantage, II export filter.
See previous entry.

W4W17F.EXE
XyWrite III Plus import filter.
See previous entry.

W4W17T.EXE
XyWrite III Plus export filter.
See previous entry.

W4W18F.EXE
GSA Navy DIF import filter.
See previous entry.

W4W18T.EXE
GSA Navy DIF export filter.
See previous entry.

W4W19F.EXE
Microsoft Rich Text import filter.
See previous entry.

W4W19T.EXE
Microsoft Rich Text export filter.
See previous entry.

W4W20F.EXE
Lotus 1-2-3 import filter.
See previous entry.

W4W21F.EXE
Excel 2.1 import filter.
See previous entry.

W4W29F.EXE
Framework III 1.0, 1.1, IV import filter.
See previous entry.

W4W29T.EXE
Framework III 1.0, 1.1, IV export filter.
See previous entry.

W4W32F.EXE
Final Form Text import filter.
See previous entry.

W4W32T.EXE
Final Form Text export filter.
See previous entry.

W4W33F.EXE
Ami Professional 1-1, 1-2, 2.0 import filter.
See previous entry.

W4W33T.EXE
Ami Professional 1-1, 1-2, 2.0 export filter.
See previous entry.

W4W44F.EXE
Word for Windows 1.0, 2.0 import filter.
See previous entry.

W4W44T.EXE
Word for Windows 1.0, 2.0 export filter.
See previous entry.

W4W770F.EXE
dBase III, III+, IV import filters.
See previous entry.

WFBG.SYN
Thesaurus file.

WORD.OVR
Dictionary file.

XONXOFF.COM
Enables XyWrite to communicate with printers using XON/XOFF protocol rather than DTR protocol.
OK to delete if no printers us XON/XOFF protocol.

XY4.DLG
Dialog file which draws the menus.

XY4.PIF
Program Information File which details the characteristics of XyWrite to Microsoft Windows for execution from within the  Windows environment.

XY4.KBD
Copy of standard internal keyboard. Editable by user.
Required only if user wants to customize keyboard.

XY4.HLP
On-line help resource. Not editable. Can not be renamed.
Delivered with help module.

XY4.MNU
All menu bar and pulldown items associated with menus.
Delivered with menus module. Delete only if menus are no longer required.

XY4-3.KBD
XyWrite III Plus keyboard style for use in XyWrite 4.